(N)HXMH(St)-J 3×1,5 mm2 Non halogen (PVC-free) electric cable, shielded
External diameter, approx. 10,4 mm
100-m-ring
På lager
Kabel til el-installasjon (skjermet, pvc-fri) NHXMH(t
Dette ar apparatet for de tekniske amatører. Apparaet gir en enkel evaluering av høyfrekvent stråling, og har en audiofunksjon som gjør at man kan høre strålingsmengden. Apparatet gir og en visning av toppverdier i tillegg til gjennomnittsverdier.
It supports all above mentioned «common advantages». The extra-broad frequency response of the UBB27 together with the features and specifications of the HFE35C offer an outstanding overview over the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.
Set offer including the following components:
– The instrument itself, based on the HF35C but with an extended frequency range reaching down to 27 MHz.
– Two antennas: The especially compensated log.-per. antenna for the range above 800 MHz and the horizontal isotropic ultra broad bandwidth antenna UBB27_G3 from 27 MHz up to far beyond 2.5 GHz (limited by the frequency response of the HFE35C).
– Small plastic case K5: with convoluted foam filler for a safe transportation of the measuring device and both antennas.
# RF-Analyzer kit HFE35C
for the easy evaluation, incl. UBB-antenna
It supports all above mentioned «common advantages». The extra-broad frequency response of the UBB27 together with the features and specifications of the HFE35C offer outstanding overview over the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.
Set offer including the following components:
* The instrument itself is based on the HF35C but has an extended frequency range reaching down to 27 MHz and comprises two antennas
* Especially compensated log.-per. antenna for the range above 800 MHz.
* Horizontal isotropic ultra broad bandwidth antenna UBB27_G3 from 27 MHz up to far beyond 2.5 GHz (limited by the frequency response of the HFE35C)
* Small plastic case K4: with convoluted foam filler for a safe transportation of the measuring device and both antenna
* Technical Data
Frequency Range: 27 MHz – far above 3.3 GHz
Measurement Range: Power flux density: 0.1 – 1999 uW/m²
Accuracy: Basic accuracy including linearity tolerance : +/- 6dB
Zero offset and rollover +/- 9 digits
Sensor: 2 antennas:
Logarithmic periodic antenna with frequeny compensation directly on the antenna
Quasiisotropic ultrabroadband antenna («omni»-characteristic) aligned for vertically polarised fields
Audio Analysis: Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control-radar) by means of an acoustic signal proportional to the modulation frequency
Stromversorgung: 9 Volt Alkaline manganese battery (included)
avarage operation time 4 – 7 hours
Low Batt. Indication
Auto-power-off
Signal Rating: Display of peak value as well as average value (switchable)
Weight: 1050 g
Dette er linken mellom amatør og profesjonelle måleapparater. Dette er apparatet for leger og alternative praktikere.Den har alle de samme funksjonene som 35C men en høyere respons og sensibilitet.
# This device supports all above mentioned «common advantages». It is especially popular among medics and alternative practitioners, as it offers a perfect combination of easy handling and professional measurement possibilities. It allows an easy allocation of the electrosmog frequencies to the traction power or the mains power as well as to the artificial harmonics, thus facilitating an especially precise consultation of remedial actions and an easy control of their effectiveness.
Has the same features and configuration as the HF35C, however additionally offers some important professional features:
– The log.-per. antenna with further improved frequency response.
– A 10 times higher sensitivity: Minimum display resolution 0.01 µW/m² .
– A measuring range extended upwards by a factor of 10: max. 19.99 mW/m² .
– Clearly simplified measurements with the help of the «peak-hold»- function.
Technical Data:
Frequency Range: 800 MHz – 2.5 GHz (3.3 GHz with increased tolerance)
Measurement Range: Power flux density: 0.01 – 19,990 µW/m²
Accuracy: Basic accuracy including linearity tolerance : +/- 6dB
Zero offset and rollover +/- 9 digits
Sensor: Optimised logarithmic periodic antenna: Less ripple, better directionality, improved shielding vs. ground
Audio Analysis: Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency
Electric power supply: 9 Volt alkaline manganese battery (included), average operation time 6 – 7 hours
Low-Batt. indication, auto-power-off
Signal Rating: Display of peak value, peak hold as well as average value (switchable)
Further Questions: 2 years warranty & long-time ex gratia agreement
Weight: 0,58 kg
Demper 20 dB maks. Egnet for alle instrumenter fra HF35 og oppover.
Dette er apparatet for de tekniske
amatører. Apparaet gir en enkel evaluering av høyfrekvent stråling, og
har en audiofunksjon som gjør at man kan høre strålingsmengden.
Apparatet gir og en visning av toppverdier i tillegg til
gjennomnittsverdier.#
This is THE device for technical amateurs –
especially easy to operate. It allows a straight forward assessment of
the exposure, a determination of suitable remedial actions, as well as a
control of their effectiveness.
Even this starter device already
combines all common advantages. The reading shows the total pollution
without any calculation required. The measured values are reliably
displayed directly in the entity corresponding to the building biology
standard values. An acoustic signal proportional to the field strength
with «Geiger-counter-effect» helps identifying regions with increased
exposure. Digital display of 1 µW/m2 up to 1999 µW/m2.
Frequency Range: 800 MHz – 2.5 GHz
Measurement Range: Power flux density: 1 – 1999 µW/m2
Accuracy: Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits
Sensor: Logarithmic periodic antenna
Audio Analysis: acoustic signal proportional to the field strength with «Geiger-counter-effect»
Signal rating: peak value
Power
supply: 9 Volt alkaline manganese battery (included), average operation
time 10 – 12 hours Low-Batt. indication, auto-power-off
Ekte 3D potensialfri måling av elektriske felt. Utvidet frekvensanalyse basert på optimalisert FFT opp til 32 KHz og bredbåndsverdier over 32 KHz. Du kan velge ekte peak målinger i bredbåndsområde. Opsjon: Integrert transientopptaker opp til 1 MHZ med mange timers opptak. Ta en kikk på Gigahertz sine sider for full oversikt! www.nfa-meters.com
An innovative step forward in the scope of LF analysis: The NFA 1000 is both, a precise 3D magnetic field logger as well as a high-resolution potential-free E-field cube, all in one meter among the professional devices (patented technology) supported by the comforting certainty of having the complete technical expertise of Gigahertz Solutions behind it.
The essence of all devices is a high-capacity processor able to analyze the field situation with an axe-specific FFT and a sampling rate of 110,000 data records per second, and to record all data on a standard SD-card. It is furthermore possible to connect external probes, and to simultaneously record the corresponding measurement values (available for high frequency and for static fields).
The easy to operate PC program NFAsoft with its revolutionary statistical functions as well as evaluation functions provides a quick overview and if necessary an analysis down to the last detail.
3D-LF-Analyser with data logger NFA 1000 for the most in-depth analysis – our masterpiece! Innovative alternative to the ME series based on a superior concept for efficient data acquisition of electric and magnetic fields, extensive long-term recordings of all relevant parameters and facilitated interpretation and documentation of the acquired data. Features: * Real 3D potential-free electric field measurement, patent pending. * 3D measurement of the magnetic field in a truly isotropic point. * Separate recordings of railway and grid frequencies as well as higher harmonics with true RMS valuation (16.6 Hz | 50/60 Hz | 100/120 Hz plus even harmonics | 150/180 Hz plus uneven harmonics | other frequencies < 2 kHz | all > 2kHz) * Measures 110,000 samples per second, the maxima of which are recorded up to 10 times per second on the 4 GB SDHC memory card supplied. Due to the simultaneous and continuous sampling of frequency and axis information you won’t miss even the smallest peaks. * Voice recording of audio notes to facilitate measurement and interpretation of recordings. * Broadband peak measurements (genuine peak of a wave) as a firmware update in preparation. * Optional, in preparation: Wireless data transfer to external display unit /PC. * Supplied with revolutionary PC evaluation software: Super fast real-time presentation, statistic functions (e.g. 95. percentile), analysis tool for Dirty Power. * Li-Ion rechargeable batteries for up to 48 hours of continuous recordings. External power supply possible (power adapter included).
FF3 er et bånpass filter tilpasset instrumentene HF35C og HF38B. Med dette filteret er det enkelt å finne hvilke strålingskilder som er dominerende. Ved hjelp av en glidebryter velger du den kilden du er interessert i (f. eks. DECT) og avleser på instrume.
Til HF 35 C, HF 38 B, HF 58 B, HF 59 B.
#Service-specific frequency filter FF3 Recommended for: HF35C, HF38B. The service specific filters always only show the preset radio service, and suppress all other frequencies.
Evaluates each radio service separately
* To be connected between the antenna cable and the antenna input socket of the measurement device (by the operator).
* Cascadable with all amplifiers and attenuators.
* Also allows a broadband measurement without additional transmission loss, which means the filter can remain attached to the measurement device.
* Comprises the most common sources of radiation.Very good selection of the chosen radio services.
* Possible exposures to sheath currents on the cable behind the filter can be additionally suppressed with the help of a free of charge modification of your HF-device. Please do not hesitate to contact us.
Frequency Range: ALL / GSM9 / GSM18 / DECT / UMTS / WLAN
Accuracy: Typical suppression of unwanted frequencies : > 25-30 dB, GSM1800 vs. DECT eff. 20-30 dB.
Power supply: 9 V battery
Målekoffert MK20 (ME3080 & HF 35 C (høy- og lavfrekvent)
Dette apparatet har de samme funksjonene som HF58B men kan i tillegg måle radarstråling.
# The radar module sets standards in this category of devices. Its functions and features are tailored to the needs and practical experiences of the building biology. Due to its comparably low price, it is often also used for scientific and industrial purposes, especially in the cell phone and wireless sector.
In addition to the full functionality of the HF58B:
– A switch for 2 MHz video bandwidth, allowing especially precise measurements, also of ultra short RADAR signals within the frequency range subject to measurement with a minimum pulse length of up to 0.5 micro seconds, as well as of UMTS-FDD/3G.
– Especially high speed of response in the operational mode peak hold (patented).
Technical Data:
Frequency Range: 800 MHz – 2.5 GHz (3.3 GHz with increased tolerance)
Measurement Range: Power flux density: 0.01 – 19,990 µW/m²
Accuracy: Basic accuracy including linearity tolerance : +/- 4.5dB
Zero offset and rollover +/- 7 digits
Sensor: Optimised logarithmic periodic antenna: Less ripple, better directionality, improved shielding vs. ground, continuous LED-monitoring of quality of connections
Audio Analysis: Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency
Electric power supply: Rechargeable highpower 9.6 Volt NiMH battery pack inside the meter, average operation time: 7 – 8 hours
Low-Batt. indication, auto-power-off
AC-adaptor for charging and long-term-operation included
Signal Rating: Display of peak value, peak hold as well as average value (switchable)
A quantitative differentiation between pulsed and un-pulsed radiation – a unique feature within the broadband measuring technology
Outputs: An AC- and a DC-output (AC: demodulated signal)
Weight: 0,82 kg
Scope of Delivery:
– Measurement device
– attachable log.-per. antenna
– incl. cable
– NiMH battery inside the meter
– mains adaptor
– battery charger
– various adaptors
– detailed instructions manual
– plastic case.
in the operational mode peak hold (patented).
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.