Beskrivelse
Magnetostatik-sonde 3D – til NFA -apparatene
kr 2 690
Enkel spenningstester, ser ut som en skrutrekker#Zur Überprüfung des phasenrichtigen Anschlusses von Elektrogeräten.
På lager
Magnetostatik-sonde 3D – til NFA -apparatene
Målekoffert MK10 (ME3030 & HF 32 D (høy- og lavfrekvent).
Dette ar apparatet for de tekniske amatører. Apparaet gir en enkel evaluering av høyfrekvent stråling, og har en audiofunksjon som gjør at man kan høre strålingsmengden. Apparatet gir og en visning av toppverdier i tillegg til gjennomnittsverdier.
It supports all above mentioned «common advantages». The extra-broad frequency response of the UBB27 together with the features and specifications of the HFE35C offer an outstanding overview over the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.
Set offer including the following components:
– The instrument itself, based on the HF35C but with an extended frequency range reaching down to 27 MHz.
– Two antennas: The especially compensated log.-per. antenna for the range above 800 MHz and the horizontal isotropic ultra broad bandwidth antenna UBB27_G3 from 27 MHz up to far beyond 2.5 GHz (limited by the frequency response of the HFE35C).
– Small plastic case K5: with convoluted foam filler for a safe transportation of the measuring device and both antennas.
# RF-Analyzer kit HFE35C
for the easy evaluation, incl. UBB-antenna
It supports all above mentioned «common advantages». The extra-broad frequency response of the UBB27 together with the features and specifications of the HFE35C offer outstanding overview over the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.
Set offer including the following components:
* The instrument itself is based on the HF35C but has an extended frequency range reaching down to 27 MHz and comprises two antennas
* Especially compensated log.-per. antenna for the range above 800 MHz.
* Horizontal isotropic ultra broad bandwidth antenna UBB27_G3 from 27 MHz up to far beyond 2.5 GHz (limited by the frequency response of the HFE35C)
* Small plastic case K4: with convoluted foam filler for a safe transportation of the measuring device and both antenna
* Technical Data
Frequency Range: 27 MHz – far above 3.3 GHz
Measurement Range: Power flux density: 0.1 – 1999 uW/m²
Accuracy: Basic accuracy including linearity tolerance : +/- 6dB
Zero offset and rollover +/- 9 digits
Sensor: 2 antennas:
Logarithmic periodic antenna with frequeny compensation directly on the antenna
Quasiisotropic ultrabroadband antenna («omni»-characteristic) aligned for vertically polarised fields
Audio Analysis: Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control-radar) by means of an acoustic signal proportional to the modulation frequency
Stromversorgung: 9 Volt Alkaline manganese battery (included)
avarage operation time 4 – 7 hours
Low Batt. Indication
Auto-power-off
Signal Rating: Display of peak value as well as average value (switchable)
Weight: 1050 g
HF/RF-Analyzer HF32D
for the easy evaluation of the HF exposure
This is the device for technical amateurs – especially easy to operate. It allows a straight forward assessment of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.
Already this starter device has all common advantages and yet it is equipped with all of the above mentioned «common features» – the only one of ist kind in this price category
* Reading shows the total pollution without any calculation required
* The measured values are reliably displayed directly in the entity corresponding to the building biology standard values, namely
* Digital display of 1 µW/m² up to 1999 µW/m².
* An acoustic signal proportional to the field strength with «Geiger-counter-effect» helps identifying regions with increased exposure.
* Measurement device
Attachable log.-per. antenna incl. Cable
Alkaline Mangan battery
Detailed instruction manual with factual background information
* Technical Data
Frequency Range: 800 MHz – 2.5 GHz
Measurement Range: Power flux density: 1 – 1999 uW/m²
Accuracy: Basic accuracy including linearity tolerance : +/- 6dB
Zero offset and rollover +/- 9 digits
Sensor: Logarithmic periodic antenna
Audio Analysis: acoustic signal proportional to the field strength with «Geiger-counter-effect»
Stromversorgung: 9 Volt Alkaline manganese battery (included)
avarage operation time 10 – 12 hours
Low Batt. Indication
Auto-power-off
Signal Rating: peak value
Further Questions: 2 years warranty
Weight: 450 g#
RF-Analyser HF32D
for an easy evaluation of the HF exposure.
This is the device for technical amateurs – especially easy to operate. It allows a straight forward assessment of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.
Even this starter device already combines all common advantages.
* The reading shows the total pollution without any calculation required.
* The measured values are reliably displayed directly in the entity corresponding to the building biology standard values.
* An acoustic signal proportional to the field strength with Geiger-counter-effect helps identifying regions with increased exposure.
* Digital display of 1 µW/m² up to 1999 µW/m².
USB data logger EL-USB3
for HF + LF devices!
» Print View
€ 78,90 incl. 19% V.A.T.
Outside EU: € 66,30
plus taxes and duties of your country
plus shipping costs
USB data logger stick for the recording of the DC output of our
measuring devices. Easy-to-operate software for a graphical evaluation
of the measured values included.
* DC-voltage data logger.
* suitable for HF58B, HF58B-r, HF59B, ME3851A, ME3951A and NFA
series.
* To be connected with an optional Gigahertz-produced adapter cable
(Logkab1+2 / 38,20 Euro).
* Logging rate adjustable from 1 s to 12 hours.
* Memorizes 32,000 measured values,voltage measuring range DC 0 to
30V
#
Attenuator DG20
suitable for: HF32D, HF35C, HF38B
Allows a measurement of major exposures.
For high exposures
* Reduces the sensitivity of the measuring device by a factor of 100 (= 20 dB).
* Adaptor plug to be connected to the antenna input socket.
USB data logger EL-USB3
for HF + LF devices!
USB data logger stick for the recording of the DC output of our measuring devices. Easy-to-operate software for a graphical evaluation of the measured values included.
» DC-voltage data logger.
» suitable for HF58B, HF58B-r, HF59B, ME3851A, ME3951A and NFA series.
» To be connected with an optional Gigahertz-produced adapter cable (Logkab1+2 / 38,20 Euro).
» Logging rate adjustable from 1 s to 12 hours.
» Memorizes 32,000 measured values,voltage measuring range DC 0 to 30V
LF Analyzer ME 3840 B (Måler lavfrekvens, med filter)