Beskrivelse
Datalogger for proffe HF og 3D-LF Analyzer
kr 790
USB data logger EL-USB3
for HF + LF devices!
USB data logger stick for the recording of the DC output of our measuring devices. Easy-to-operate software for a graphical evaluation of the measured values included.
» DC-voltage data logger.
» suitable for HF58B, HF58B-r, HF59B, ME3851A, ME3951A and NFA series.
» To be connected with an optional Gigahertz-produced adapter cable (Logkab1+2 / 38,20 Euro).
» Logging rate adjustable from 1 s to 12 hours.
» Memorizes 32,000 measured values,voltage measuring range DC 0 to 30V
Datalogger for proffe HF og 3D-LF Analyzer
Målekoffert MK10 (ME3030 & HF 32 D (høy- og lavfrekvent).
Low
frequency analyser ME3830B– for an easy evaluation of LF-exposure
This is THE
device for technical amateurs – especially easy to operate. It supports all
above mentioned «common advantages» and it allows a straight forward
assessment of the exposure, a determination of suitable remedial actions, as
well as a control of their effectiveness.
Comprises
all features of the ME3030B, and additionally offers:
Connection cord with open end
0,75 mm2, 3 meters, black
Dette er apparatet for de tekniske
amatører. Apparaet gir en enkel evaluering av høyfrekvent stråling, og
har en audiofunksjon som gjør at man kan høre strålingsmengden.
Apparatet gir og en visning av toppverdier i tillegg til
gjennomnittsverdier.#
This is THE device for technical amateurs –
especially easy to operate. It allows a straight forward assessment of
the exposure, a determination of suitable remedial actions, as well as a
control of their effectiveness.
Even this starter device already
combines all common advantages. The reading shows the total pollution
without any calculation required. The measured values are reliably
displayed directly in the entity corresponding to the building biology
standard values. An acoustic signal proportional to the field strength
with «Geiger-counter-effect» helps identifying regions with increased
exposure. Digital display of 1 µW/m2 up to 1999 µW/m2.
Frequency Range: 800 MHz – 2.5 GHz
Measurement Range: Power flux density: 1 – 1999 µW/m2
Accuracy: Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits
Sensor: Logarithmic periodic antenna
Audio Analysis: acoustic signal proportional to the field strength with «Geiger-counter-effect»
Signal rating: peak value
Power
supply: 9 Volt alkaline manganese battery (included), average operation
time 10 – 12 hours Low-Batt. indication, auto-power-off
#
Attenuator DG20
suitable for: HF32D, HF35C, HF38B
Allows a measurement of major exposures.
For high exposures
* Reduces the sensitivity of the measuring device by a factor of 100 (= 20 dB).
* Adaptor plug to be connected to the antenna input socket.
Power connection cable, black, 5m, 3×1,5mm2, Schuko and socket, EN 60320
Power connection cord, black,0,5m, 3×1,0mm2, Schuko plug to socket, EN 60320
LF Analyzer ME 3840 B (Måler lavfrekvens, med filter)